<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xml:lang="ru">
  <front xmlns:xlink="http://www.w3.org/1999/xlink">
    <journal-meta>
      <journal-title-group>
        <journal-title>St. Petersburg Polytechnic University Journal: Physics and Mathematics</journal-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Научно-технические ведомости СПбГПУ. Физико-математические науки</trans-title>
        </trans-title-group>
      </journal-title-group>
      <issn pub-type="epub">2304-9782, 2618-8686, 2405-7223</issn>
    </journal-meta>
    <article-meta xmlns:xlink="http://www.w3.org/1999/xlink">
      <article-id pub-id-type="publisher-id">10</article-id>
      <article-id pub-id-type="doi">10.18721/JPM.17410</article-id>
      <title-group>
        <article-title>The efficiency of a focusing system when ion current transporting to the differential pumping system of a mass spectrometer</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Эффективность фокусирующей системы при транспортировке ионного тока в систему дифференциальной откачки масс-спектрометра</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Pomozov</surname>
            <given-names>Timofey</given-names>
          </name>
          <xref ref-type="aff" rid="aff1"/>
          <email>tim-kor@mail.ru</email>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Muradymov</surname>
            <given-names>Marat</given-names>
          </name>
          <xref ref-type="aff" rid="aff1"/>
          <email>m.muradymov@gmail.com</email>
        </contrib>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0009-0003-8001-7469</contrib-id>
          <name>
            <surname>Tkach</surname>
            <given-names>Egor</given-names>
          </name>
          <xref ref-type="aff" rid="aff1"/>
          <email>egorka765@gmail.com</email>
        </contrib>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0002-0547-987X</contrib-id>
          <name>
            <surname>Yavor</surname>
            <given-names>Mikhail</given-names>
          </name>
          <xref ref-type="aff" rid="aff2"/>
          <email>mikhail.yavor@gmail.com</email>
        </contrib>
      </contrib-group>
      <aff id="aff1">Institute for Analytical Instrumentation of the RAS</aff>
      <aff id="aff2">Institute for Analytical Instrumentation RAS</aff>
      <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2024-12-31">
        <day>31</day>
        <month>12</month>
        <year>2024</year>
      </pub-date>
      <volume>17</volume>
      <issue>4</issue>
      <fpage>114</fpage>
      <lpage>120</lpage>
      <self-uri xmlns:xlink="http://www.w3.org/1999/xlink" content-type="pdf" xlink:href="https://physmath.spbstu.ru/userfiles/files/articles/2024/4/10_114-120_17(4)2024.pdf"/>
      <abstract xml:lang="en">
        <p>In this work, a charge particle beam transport in a corona discharge ion source with a thin diaphragm focusing system taking into account the gas-dynamic flow in the vicinity of the nozzle has been studied experimentally. The space of influence of the gas-dynamic flow on the ion transport in the vicinity of the nozzle was shown not to exceed two nozzle diameters. The results of comparing the efficiency of the ion beam transport in the ion source with using the focusing system and without it are presented. Using the focusing system allowed one to triple the current entering the collector and to raise the sum of currents entering the nozzle and collector by an order of magnitude.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>ion source</kwd>
        <kwd>mass spectrometer</kwd>
        <kwd>differential pumping system</kwd>
        <kwd>focusing system</kwd>
        <kwd>ion transport</kwd>
      </kwd-group>
    </article-meta>
  </front>
</article>
