<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xml:lang="ru">
  <front xmlns:xlink="http://www.w3.org/1999/xlink">
    <journal-meta>
      <journal-title-group>
        <journal-title>St. Petersburg Polytechnic University Journal: Physics and Mathematics</journal-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Научно-технические ведомости СПбГПУ. Физико-математические науки</trans-title>
        </trans-title-group>
      </journal-title-group>
      <issn pub-type="epub">2304-9782, 2618-8686, 2405-7223</issn>
    </journal-meta>
    <article-meta xmlns:xlink="http://www.w3.org/1999/xlink">
      <article-id pub-id-type="publisher-id">6</article-id>
      <article-id pub-id-type="doi">10.5862/JPM.230.6</article-id>
      <title-group>
        <article-title>The criterion for the optimal sampling of copper thermistor to measure in the atmosphere under normal conditions</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Критерий оптимального выбора медного термосопротивления для измерений в атмосфере при нормальных условиях</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Oktyabrskiy</surname>
            <given-names>Valeriy</given-names>
          </name>
          <email>vokt@yandex.ru</email>
        </contrib>
      </contrib-group>
      <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2015-12-10">
        <day>10</day>
        <month>12</month>
        <year>2015</year>
      </pub-date>
      <issue>4</issue>
      <issue-id pub-id-type="publisher-id">230</issue-id>
      <fpage>73</fpage>
      <lpage>76</lpage>
      <self-uri xmlns:xlink="http://www.w3.org/1999/xlink" content-type="pdf" xlink:href="https://physmath.spbstu.ru/userfiles/files/articles/2015/4/06_73_76_4_230_2015.pdf"/>
      <abstract xml:lang="en">
        <p>In this paper a new parameter is suggested as a criterion for selecting the optimal value of the copper thermal resistance in temperature measurements in the atmosphere under normal conditions. The proposed parameter is directly proportional to the sensitivity of thermal resistance and inversely proportional to the product of ‘dead’ resistance and ‘dead’ temperature (the product of errors of temperature and resistance when their determination). It has been shown through the example of 4 samples that this criterion is convenient. For one of the thermal resistance this parameter is higher in the investigated range of temperatures.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>selection criterion</kwd>
        <kwd>copper thermistor</kwd>
        <kwd>temperature measurement</kwd>
        <kwd>‘dead’ resistance</kwd>
        <kwd>‘dead’ temperature</kwd>
      </kwd-group>
    </article-meta>
  </front>
</article>
