<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xml:lang="ru">
  <front>
    <journal-meta>
      <journal-title-group>
        <journal-title>St. Petersburg Polytechnic University Journal: Physics and Mathematics</journal-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Научно-технические ведомости СПбГПУ. Физико-математические науки</trans-title>
        </trans-title-group>
      </journal-title-group>
      <issn pub-type="epub">2304-9782, 2618-8686, 2405-7223</issn>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">7</article-id>
      <title-group>
        <article-title>An estimation of photon beams parameters in the remote radiation treatment from ionization matrices</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Оценка параметров фотонных пучков в дистанционной лучевой терапии по данным ионизационных матриц</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Mironov</surname>
            <given-names>Vladimir</given-names>
          </name>
          <email>vladimir.mironov@ymail.com</email>
        </contrib>
      </contrib-group>
      <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2012-03-10">
        <day>10</day>
        <month>03</month>
        <year>2012</year>
      </pub-date>
      <issue>1</issue>
      <issue-id pub-id-type="publisher-id">141</issue-id>
      <fpage>45</fpage>
      <lpage>53</lpage>
      <abstract xml:lang="en">
        <p>A comparative estimation for inaccuracy in profile dependency of photon beams with the energy of 6 MeV has been considered using experimental data from ionization matrices and water phantom with ionization chambers. The regions of practicality for a matrix to test the photon 6 MeV beams quality under the clinical conditions were analyzed. The practical recommendations are given how to carry out the optimizing procedure of dosimetric experimental data during the analysis of therapeutic beam fields.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>quality control</kwd>
        <kwd>radiation therapy</kwd>
        <kwd>dosimetry</kwd>
        <kwd>ionization matrices</kwd>
        <kwd>profile inaccuracy</kwd>
        <kwd>photon optimization algorithms</kwd>
      </kwd-group>
    </article-meta>
  </front>
</article>
